A delivery sheet says a programme runs exactly one hour. Ingest measures one hour and 3.6 seconds. Before asking the editor to cut the credits, find out how the sheet counted the hour. At 29.97 frames per second, the same four pairs of digits can point to different pictures depending on the timecode convention.
Where the 3.6 seconds come from
Take a master that plays at exactly 30,000/1,001 frames per second. Start counting at zero. Under non-drop-frame timecode (NDF), each nominal second has 30 numbered frames. The boundary labelled 01:00:00:00 therefore sits 108,000 frames from the start. At the actual playback rate, those frames take 3,603.6 seconds. A sheet that treats that label as 3,600 seconds understates the running time.
Drop-frame timecode (DF) keeps the labels close to elapsed time by skipping two frame numbers at the start of each minute except every tenth minute. Across one hour it skips 108 labels. The boundary labelled 01:00:00;00 sits 107,892 frames from zero, or 3,599.9964 seconds. Every picture still plays. The change is in the numbering, as the Avid Media Composer guide illustrates at a minute boundary.
Find the convention on the receiving system
Load a constant-rate test clip with known source timecode. In a source-timecode display, step one picture past 00:00:59;29. A 29.97 DF counter advances to 00:01:00;02. Repeat at the tenth minute: 00:09:59;29 advances to 00:10:00;00. On the NDF version, the first minute begins at 00:01:00:00. This gives the receiving operator two transitions to check even if a spreadsheet has replaced every semicolon with a colon.
Make sure the number on screen belongs to the clip. A sequence can start at a different hour, and a monitor can show a sequence counter or a frame count instead of the embedded source label. Adobe’s timecode display guide describes the display choices. For teams still exchanging legacy Final Cut Pro XML, Apple’s elements reference documents the timecode display-format field. Check what the destination actually imported.
Decide whether the master needs an edit
Put the same visible event under the playhead at each end of the handoff: the first frame of a white flash, for example. Record its frame offset from the agreed start and its displayed label. For the duration comparison, specify whether the out point means the last included frame or the first frame after the programme. That detail alone can account for a one-frame discrepancy.
If both systems land on the same flash at the same frame offset and give the same total frame count at the same playback rate, preserve the master. Correct the timecode convention on the cue sheet or in the import settings and regenerate the affected cues. If the frame counts themselves differ, the label convention cannot explain the missing or extra pictures. Compare the actual in and out frames before authorizing a trim.
Cover photograph: KEXP video editing room, Seattle, April 2016, by Joe Mabel. Archival photograph, cropped and JPEG-encoded. This derivative is licensed under CC BY-SA 4.0.